KONOTOP VALVES PLANT

CONTROL VALVE WITH PNEUMATIC ACTUATOR PN 6,4; 16

To be installed on pipelines to control flow rate of liquids, vapors or gases which are not corrosive for materials of control element.

The plant manufactures control valves with pneumatic actuator of several types: from POU-7 to POU-12.

The assemblies operate in regions with temperate, cold or tropical climate.



Table  1

Product Dimensions, mm
h L l H
POU-7 70 130 - 541
555
POU-8 180 - 541
190 555
POU-9 90 235 635
95 680
POU-10 70 - 565
585
POU-11 100 - 565
585
POU-12 180 235 665
685


Table  2

Type PN,
MPa
DN,
mm
Temperature, 0C Material Option Flow rate, Kvy, m3/h Weight,
kg
fluid ambient
POU-7 6,4 15 from -40

to +225
from -30

to +50
AISI 1020,
AISI 321
straight-through,
female threated
0,006; 0,016; 0,04;
0,1; 0,16; 0,25; 0,4;
0,6; 1,0; 1,6; 2,5
16,4
20 1,6; 2,5 19,4
POU-8 16 15 AISI 1020,
AISI 321,
AISI 316 Ti
straight-through,
flanged
0,006; 0,016; 0,04;
0,1; 0,16; 0,25; 0,4;
0,6; 1,0; 1,6; 2,5
19,1
20 1,6; 2,5; 4,0; 6,3 22,8
POU-9 15 from +225

to +450
AISI 1020,
AISI 321
0,006; 0,016; 0,04;
0,1; 0,16; 0,25; 0,4;
0,6; 1,0; 1,6; 2,5
23,6
20 1,6; 2,5; 4,0; 6,3 25,0
POU-10 6,4 15 from -40

to +225
angle,
female threated
0,006; 0,016; 0,04;
0,1; 0,16; 0,25; 0,4;
0,6; 1,0; 1,6; 2,5
16,4
20 1,6; 2,5 19,4
POU-11 16 15 AISI 1020,
AISI 321,
AISI 316 Ti
angle
flanged
0,006; 0,016; 0,04;
0,1; 0,16; 0,25; 0,4;
0,6; 1,0; 1,6; 2,5
22,9
20 1,6; 2,5; 4,0; 6,3 22,3
POU-12 15 from +225

to +450
AISI 1020,
AISI 321
0,006; 0,016; 0,04;
0,1; 0,16; 0,25; 0,4;
0,6; 1,0; 1,6; 2,5
22,9
20 1,6; 2,5; 4,0; 6,3 24,1


Design options of Control Valve with Pneumatic Actuator PN 6,4; 16

      


Main design features and advantages

  • Actuator that includes diaphragm and spring transforms the change of the incoming signal to the movement of stem that is rigidly connected to valve gate.
  • Actuator also includes coiled gasket which provides sealing over three surfaces with the use of one set of fasteners.
  • Actuator operates with the change of hydraulic resistance of valve that depends on the change of it's bore versus gate travel. When there is no compressed air in the working chamber then spring moves stem to an extreme position: the upper one for the actuators that are opened in normal position and the lower one for that closed.
  • Models POU-9 and POU-12 have lubricators for grease injection to grease chamber.